Municipal Exhibitions and Congress of Ávila |
- |
Name: Municipal Exhibitions and Congress of Ávila
Architect: Francisco Mangado
Builder: Volconsa S.A.
Execution date: 2005 - 2009
Granite: Amarillo Villarreal abujardado y arenado
Placer: Sucomaga (Madrid) www.sucomaga.com
System of placing of the facade: Sucomaga (Madrid) www.sucomaga.com
|
|
Description:
Ventilated facade of
granite Villarreal of 5cm of
thickness, fixed with punctual
anchorage of stainless steel
type Z100x40x5mm on
structure of armed concrete.
False ceiling of granite of 4cm,
fixed by means of punctual
anchorages double type
Z40x40x3mm to tubular
substructure hanged of stainless
steel 50x30x3mm.
Floating cover realised with
granite of 4 cm of thickness
on plots of PVC regulables.
Cover formed by planes
bent realised with
granite of 4 cm of thickness
fixed by means of punctual
anchorages type Z40x40x3mm
to structure of stainless steel
40x40x3mm.
|
To the right they show
images of the development of
the execution of the ventilated
facade, from the wall
going through the placing
of the metal section until
the placing of the cladding of
yellow granite Villarreal.
Cover hit to the estrucutra
of granite (finished cut-
quarry) with mechanical
anchorage.
Underneath it goes anchored
to a cover formed by smooth
sheet 8mm+layer compression
HAS-25 and:8cm +plate of
pvc+poliestireno extruído and:
5cm+geotextil +mortar of
protectio.
1. Forged composite slab (Aceralia or similar) PL58/150 (esp. depending on structure).
2. Forming of lightened concrete slope.
3. PVC waterproofing lamina.
4. Extruded polystyrene e=5 cm.
5. Geotextile lamina.
7. Roofing granite on PVC plots; e=5cm.
10. Reinforced concrete wall e=40 cm.MH-40.
11. Exterior projected polyurethane insulation + plastic paint =5cm+air chamber+exterior granite covering e=78cm obtained by splitting with wedges, AE-pi1(natural finish on the split).
12. Concealed galvanized steel folded sheet gutter e=3mm.
13. Ext. Carpentry +6+6 mm glazing with sandwiched translucent Butiral (according to technical specs)
14. Double external + carpentry glass 10+10mm with interposition of butiral transparent (according to esp. technicians)
15. Reinforced of concrete of arlita and:10cm + layer of mortar with armed upper and:4cm.
18. Exterior 10x10x10 cm cut granite block with key mortar
24. Draining lamina (Delta-drain type) + geotextile fitted on bituminous primer. AE-imp 4.
38. Cub.sheet colb. PL150/59+ layer compresion HAS-25. layer of pvc + extruded polystyrene e:5cm + extruded polystyrene e:5cm + geotextile + mortar of protection.
39.Granite covering (cut-quarry finish) with mechanical anchoring.
40. Exterior sealing formed by sheet iron e=10 mm.
41. Carpentry of glass of 5+5mm with interposition of fibre of glass.
42. Reinforced concrete wall e:25mm HA-25.
43. Wall of block of concrete vibratepressing 40x20x10
MB-10.
Detail of punctual anchorage in ventilated facade |
It detail subjection of false ceiling of granite |
|
|